THERMOCOUPLE REPLACEMENT INSTRUCTIONS - NATURAL GAS MODELS (ALL MODELS EXCEPT 30T)Kit Contents: 1 <strong>Thermocouple</strong> and 1 <strong>Thermocouple</strong> ClipIMPORTANT: For correct water heater operation, it is essentialthat the thermocouple assembly be properly installed. If you lackthe necessary skills to properly perform the installation, you shouldnot proceed, but get help from a qualified service technician.1. Before performing any maintenance it is important to turn offthe gas supply to the water heater at the manual gas shut-offvalve. This valve is typically located beside the water heater.Note the position of the shut-off valve in the open/on positionthen proceed to turn it off.2. On the lower front of the water heater locate the combinationgas control valve/thermostat. (See Figure 1) Depress and holdthe lock tab located under the gas control knob on the right.Rotate the gas control knob on the combination gas controlvalve/thermostat clockwise until “OFF” aligns with the mark onthe front of the gas valve. Once the gas supply has been shutoff,remove outer door. (See Figure 1)3. Using a 1/4” nut driver or socket loosen the two screws securingthe manifold door assembly until they are free. Do nottotally remove the screws and plastic retainer washers fromthe manifold door. The screws and retainer washers will beneeded to reattach the manifold door. (See Figure 1)4. In this step, the thermocouple, manifold tube, pilot tube andigniter wire will be disconnected from the combination gascontrol valve/thermostat. (See Figure 2) Using a 7/16” wrenchdisconnect the thermocouple (left-hand thread) and pilot tube(right-hand thread). Using a 3/4” wrench disconnect the manifoldtube (right-hand thread). Carefully pull the igniter wire fromthe igniter button.5. Grasp the manifold tube and push down slightly to free themanifold tube, pilot tube, and thermocouple from the combinationgas control valve/thermostat. Carefully remove the manifoldassembly from the burner compartment. BE SURE NOTTO DAMAGE INTERNAL PARTS.6. With the manifold assembly removed, use a brush (a toothbrushworks well) and/or vacuum to clean the flame arrestorboth top and bottom. (See Figure 3) It is important to cleaninside the combustion chamber and underneath the waterheater. In lint/dust prone areas such as laundry rooms, it isrecommended that the Filter Accessory Kit (part number:6910609 or 6910610) be installed. NOTE: Anytime maintenanceis performed on the combustion chamber it is recommendedthat the flame arrestor be cleaned inside and out.7. Once the manifold assembly is removed from the water heater,locate the retainer clip securing the two-piece wire connectorto the manifold door. (Note the orientation of the retainerclip). Insert the tip of a large flat head screwdriver between theclip and the top of the two-piece wire connector. (See Figure4) Carefully rotate the screwdriver to raise the clip.8. With the retainer clip removed carefully push the two-piecewire connector through the manifold door. It may be necessaryto slide the connector out one piece at a time. Keep the twopiecewire connector and retainer clip for re-installation.Figure 1Gas Control KnobFigure 2<strong>Thermocouple</strong>Figure 3<strong>Thermocouple</strong>Manifold TubeManifold DoorScrewsManifoldTubeVacuumPilotTubeLock TabMarkIgniter WirePilot TubeFlame ArrestorIgniter WireFlame ArrestorManifoldDoorOuter Door6510344February 20051
- Page 2 and 3: 9. Locate the clip holding the ther
- Page 4: THERMOCOUPLE BENDING TEMPLATE\INSTR
EN
EnglishDeutschFrançaisEspañolPortuguêsItalianoRomânNederlandsLatinaDanskSvenskaNorskMagyarBahasa IndonesiaTürkçeSuomiLatvianLithuaniančeskýрусскийбългарскиالعربيةUnknown
Self publishing
Login to YUMPU News Login to YUMPU Publishing
CLOSE- TRY ADFREE
- Self publishing
- Discover
-
products
News Publishing
- Magazines
- Pricing
-
Login to YUMPU News Login to YUMPU Publishing
24.11.2014 • Views
Share Embed Flag
Flame Guard® Replacement Parts - American Water Heaters
Flame Guard® Replacement Parts - American Water Heaters
SHOW MORE
SHOW LESS
ePAPER READ
DOWNLOAD ePAPER
- TAGS
- assembly
- manifold
- replacement
- prefix
- anode
- valve
- viewport
- heater
- burner
- gasket
- heaters
- www.americanwaterheater.com
americanwaterheater.com
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
START NOW
- More documents
- Similar magazines
- Info
<strong>Flame</strong> Guard® <strong>Replacement</strong> <strong>Parts</strong>
- Page 2 and 3: Replacement Parts Illustration No.
- Page 4: Order Entry and Sales 500 Princeton
Delete template?
Are you sure you want to delete your template?
Save as template?
Title
Description
no error
products
- FREE
- adFREE
- WEBKiosk
- APPKiosk
- PROKiosk
Resources
- Blog
- API
- Help & Support
- Status
- tuxbrain.com
- ooomacros.org
- nubuntu.org
Company
- Contact us
- Careers
- Terms of service
- Privacy policy
- Cookie policy
- Cookie settings
- Imprint
Terms of service
Privacy policy
Cookie policy
Cookie settings
Imprint
Made with love in Switzerland
© 2022 Yumpu.com all rights reserved